Skip to main content

Mini Cooper (R50) L4-1.6L (W10) A/C - Poor Or No Cooling

2002 Mini Cooper (R50) L4-1.6L (W10) Page 1

Vehicle: All Technical Service Bulletins
A/C - Poor Or No Cooling
SI M64 01 08
Heating and Air Conditioning

November 2012
Technical Service

This Service Information bulletin supersedes SI M64 01 08 dated August 2008.

[NEW] designates changes to this revision

SUBJECT
Air Conditioning System Leak Testing

MODEL
R55
R56
[NEW] R57
[NEW] R58
[NEW] R59
[NEW] R60

SITUATION
The customer complains of poor or no air conditioning cooling. After further

diagnosis, the system is found to be low or empty of a refrigerant charge, but when using an electronic leak detector, no leak can be found.


CAUSE

In most cases, an electronic leak detector is not sufficient for identifying small leaks in the system. Electronic leak detectors can give false alarms and can lead to an improper diagnosis of small leaks. A leak cannot be located exactly if accessibility is impaired (in the case of the expansion valve, evaporator or condenser).

PROCEDURE

Always use proper eye and hand protection whenever servicing air conditioning systems. Refer to repair manual RA 64 50 for further information.


  1. Always troubleshoot and correct any faults in the IHKA/IHKR (Independent Heating and Air Conditioning) system before proceeding further.


  1. If the source of the leak is difficult to detect, the evaporator and condenser area needs to be checked further for leaks.

  1. A special testing adapter set (64 5 120) has been developed, which allows pressure testing of the air conditioning evaporator and condenser while still installed in the vehicle.

This prevents a lot of unnecessary disassembly of the vehicle for diagnosis purposes.






















  1. In order to use this adapter set, the following auxiliary materials will be needed:


2002 Mini Cooper (R50) L4-1.6L (W10) Page 2


  • Nitrogen (in pressurized cylinder) obtained locally. Ensure that employees are advised of how to handle pressurized cylinders correctly (danger of asphyxiation). For this purpose, follow the notes and instructions in the technical safety specifications available from the gas supplier.

  • Nitrogen tank set with pressure reducer (available via the dealer equipment program).

  1. If the evaporator or condenser is suspected of leaking, recover the remaining refrigerant from the system, using a BMW approved refrigerant recovery machine.

  1. Refer to the repair manual instructions "RA 64 51 Leak-testing condenser" for instructions on which adapters are needed, and the procedure for checking the condenser for leaks while installed in the vehicle.




















  1. Once the proper adapters have been fitted, connect the nitrogen bottle (1) with the pressure reducer (2) to the pressure gauge (3). Connect the special hose (64 5 121) to the fitting on the pressure gauge and the test adapter on the vehicle.

Note:
  • The testing apparatus must be leakproof.

  • Ambient temperature and the temperature of the vehicle must not change significantly during the test procedure.

  • The vehicle must not be moved during the test period.




















  1. Ensure that the regulator (1) is backed off and the flow shutoff valve (2) is closed.

  1. Open the nitrogen bottle valve slowly.

  1. Open the valve (2) to the full open position. Note: the valve is shown in the closed position.

  1. Apply a test pressure of 10 bar (150 psi) slowly by turning the pressure regulator (1) clockwise.

  1. A pressure of 20 bar (280 psi) must not be exceeded, as this will damage the evaporator or other system components.


2002 Mini Cooper (R50) L4-1.6L (W10) Page 3


  1. Once the test pressure of 10 bar (150 psi) is reached, close the valve (2). Back off the regulator and close the nitrogen bottle valve.

  1. Check the leak tightness of the testing apparatus and of the connections at the adapters.

  1. Monitor the pressure over a period of 2 hours. The maximum allowable pressure loss is 1.5 bar, giving a minimum reading of 8.5 bar.





















  1. If there is a pressure loss of greater than 1.5 bar, this indicates that there is a leak in the evaporator or condenser, depending on which component is being tested.

  1. Release the residual pressure from the line, using the pressure relief valve.

  1. Replace the evaporator or condenser as needed. After leak testing and repair:

  • Retest the system using the same procedure to ensure that there are no leaks.

  • Release all pressure from the test hose slowly.

  • Replace all sealing rings and moisten with refrigerant oil before reassembly.

  • Evacuate and fill the system.

[NEW] WARRANTY INFORMATION
Not applicable.

Comments